Technical information
Applications
Industries
Downloads

The RHT constant wattage heating cables provide reliable freeze protection for rails, switches, tramways, and monorails thanks to their custom design, constant wattage of up to 220 W/m, and fast installation tailored to the specific dimensions of railway systems.

Product Specification – Maximum Allowable Exposure Temperature: 350 °C
Maximum Continuous Exposure Temperature

350°C

Maximum Intermittent Exposure Temperature

425°C

Minimum Installation Temperature

-65°C

Power Supply

230 or 115 VAC (nominal)

Dimensions (mm ±0.5)

10,0 x 7,0

Minimum Bending Radius

RHT – 25 mm

Weight (kg/100 m)

RHT – 16,5 kg

Thread Diameter for Cable Gland

RHT – M20

Maximum Circuit Length (m)

Output Power

Maximum Circuit Length*

(Nominal) Zone Length

(W/m)

115V - 230V

115V - 230V

100

16m - 32m

Zone lengths may vary.

150

13m - 26m

Zone lengths may vary.

220

11m - 22m

Zone lengths may vary.

*For a 10% power variation between both ends

Power Conversion Factors

115 V Heating Cable

230 V Heating Cable

277 V: multiply the power by 5.80

277 V: multiply the power by 1.45

230 V: multiply the power by 4.00

240 V: multiply the power by 1.09

208 V: multiply the power by 3.27

220 V: multiply the power by 0.91

120 V: multiply the power by 1.09

208 V: multiply the power by 0.82

110 V: multiply the power by 0.91

115 V: multiply the power by 0.25

Please contact us for any specific requirements.

RHT Constant Wattage Heating Cables are specifically engineered for freeze protection of railways, points (switches), tramways and monorails.

Application Example:
The RHT heating cable is applied to rail tracks, switch points and transport systems (mainline rail networks, tramways, monorails) to ensure reliable operation under winter conditions.

Problem Example:
Without protection, snow and ice can obstruct switch points, disrupt traffic flow and lead to significant maintenance and operational costs.

The Solution – RHT

The RHT heating cable is a constant wattage, robust, parallel-resistance heating system with a durable aluminium outer sheath.

-Available as factory-terminated lengths or on reels for on-site cutting.

-Easy to install and fully compatible with existing systems.

-Designed and tested in accordance with international railway switch heating standards.

Constant Wattage Heating Cables – Heat Tracer (RHT) are applied across a wide range of industries and environments, including:

-Railway infrastructure

-Tramway networks and urban transit / Monorails and automated metros

-Transportation systems in cold or mountainous climates

-Chemical & petrochemical facilities

-Machinery and equipment manufacturers

-Food & beverage industry

-General industrial applications

This list is not exhaustive.

Constant Wattage Heating Cable Range