Constant Wattage Heating Cables – Heat Tracer (RHT)
Our RHT rail heater heating cables are parallel resistance, constant wattage heating cables designed for use on mainline switch systems, electrified third rails, monorails, and tramway systems.
The RHT constant wattage heating cable is a cut-to-length cable designed to keep systems free of snow and ice, ensuring operational track integrity in winter conditions.
When used for spot heating systems, the RHT is intended to be pre-terminated in 3m, 4m, 5m, and 6m lengths to match switch dimensions.
This heating cable is designed for use with standard, railway-approved heater fixing clips.
A thermally insulated end cap is available if required.
Please contact us for any specific requirements.

RHT constant wattage heating cables provide reliable freeze protection for rails, switches, tramways, and monorails thanks to their custom design, constant power output of up to 220 W/m, and quick installation tailored to the specific dimensions of railway systems.
Continuous Maximum Exposure Temperature | 350°C (644°F) |
---|---|
Intermittent Maximum Exposure Temperature | 425°C (797°F) |
Minimum Installation Temperature | -65°C (-85°F) |
Power Supply | 230 or 115 VAC (nominal) |
Dimensions (mm ± 0.5) | 10,0 x 7,0 |
Minimum Bending Radius | RHT – 25 mm |
Weight (kg/100 m) | RHT – 16,5 kg |
Cable gland | RHT – M20 |
Output power | Maximum circuit length* | (Nominal) zone length |
---|---|---|
(W/m) | 115V - 230V | 115V - 230V |
100 | 16m - 32m | Zone lengths may vary. |
150 | 13m - 26m | Zone lengths may vary. |
220 | 11m - 22m | Zone lengths may vary. |
*For a 10% power variation between both ends
115 V heating cable | 230 V heating cable |
---|---|
277 V : Multiply the power by 5,80 | 277 V : Multiply the power by 1,45 |
230 V : Multiply the power by4,00 | 240 V : Multiply the power by 1,09 |
208 V : Multiply the power by par 3,27 | 220 V : Multiply the power by 0,91 |
120 V : Multiply the power by 1,09 | 208 V : Multiply the power by 0,82 |
110 V : Multiply the power by 0,91 | 115 V : Multiply the power by 0,25 |
Please contact us for any specific requirements.
The RHT constant power heating cables are specifically designed for frost protection of railway tracks, switches, trams, and monorails.
This parallel resistance heating cable, cut to length, keeps systems free of snow and ice, ensuring reliable operation in winter conditions. Easy to install, heating cables are available in pre-terminated heated lengths (3 to 6 meters) to fit switch dimensions and can directly replace existing heating systems.
Compatible with standard railway industry fastening clips, these heating cables support power ratings up to 220 W/m and operate at 115 or 230 V AC, with options up to 1000 V AC/DC for third rails.
Constant Power Heating Cables – Heat Tracer (RHT) are used in the following sectors:
-Railway
-Tramway and urban transport networks / Monorails and automated metro systems
-Transportation systems in cold or mountainous climates
-Chemical & petrochemical industry
-Machinery manufacturing
-Food industry
-Various industries
This list is not exhaustive.