Technical information
Applications
Industries
Downloads

The Contact Rail Heater (CRH) is a self-regulating heating cable specially designed for contact rails and third rails under 750 V DC systems. It provides reliable protection against ice and snow buildup, while automatically adapting to temperature changes. The CRH ensures quick installation and optimal resistance up to 250 °C, even in demanding railway environments.

CRH self-regulating heating cables are engineered to withstand the specific stresses of railway conditions, such as severe and continuous vibrations caused by traffic, immersion in icy water, snow, herbicides, diesel oils, lubricating oils, oxalic acid, and de-icing fluids. These heating cables can operate fully or partially exposed to air without compromising their service life.

Installation of the CRH cable is fast and straightforward, requiring no special skills or tools. Both new and replacement heating cables can be easily and quickly installed, minimizing track occupation time and reducing disruptions to rail traffic.

Maximum allowable temperature

250°C (482°F)

Maximum operating temperature

250°C (482°F)

Minimum installation temperature

-40ºC (-40ºF)

Power supply

Up to 1000 volts (AC ou DC)

Rated power

Up to 130 W/m

Cable dimensions

13.6 x 4.8mm +/- 0.5mm

Minimum bending radius

40mm

Weight (kg/100 m)

15.7 kg

Maximum braid resistance

18.2 Ohm/km

Cable Gland

M25

 

Maximum circuit length (m) according to breaker size

Reference

 

Starting temperature (°C)

 

230V

16A

20A

32A

50A

90CRH6

0

84

104

166

208

-10

68

84

136

208

-20

56

72

114

178

To be used with type C circuit breakers compliant with IEC 60898 standard.

The CHR self-regulating heating cable is designed to prevent ice formation on contact rails and third rails of railway networks, ensuring operational continuity and traffic safety even under harsh winter conditions.

Its robust design allows for direct replacement of existing heaters, with secure mounting using specialized clips and FRP channels, providing resistance to vibrations, immersion in icy water, chemical agents, and oils commonly encountered on rail tracks.

Thanks to its self-regulating technology, the cable automatically adjusts its power output according to surface temperature, minimizing energy consumption while ensuring consistent protection. Its straightforward installation enables quick deployment with minimal impact on railway traffic.

Self-regulating heating cables – Contact Rail Heaters (CRH) are used in the following sectors:

-Railway transportation

-Urban infrastructure and tramways

-Chemical & petrochemical industries

-Machinery manufacturing

-Construction

-Food processing

-Various industries

This list is not exhaustive.

Self-Regulating Heating Cable Range