FSE/FSEw Self-Regulating Heating Cables – Tmax 100 °C
FSE and FSEw are self-regulating heating tapes designed for freeze protection and temperature maintenance of pipes and vessels.
They can be cut to length directly on site, allowing custom installations without design constraints.
These cables are certified to CNEX, DNV, ATEX, IEC, IECEx and CE standards. Suitable for both hazardous and non-hazardous areas in compliance with international regulations, they ensure optimal safety even in the most demanding environments.
Thanks to their self-regulating technology, the heating tapes automatically adjust their output according to the surface temperature.
They will not overheat or become damaged, even when overlapped.
For specific requirements, please contact us.

The Freezstop Extra (FSE) industrial self-regulating heating tape ensures effective freeze protection and temperature maintenance of pipes and tanks.
Its ability to be precisely cut to length on site, combined with its intrinsic safety and robustness, makes it a reliable and easy-to-install solution, even in hazardous areas.
Product Specifications – Maximum Exposure Temperature: 100 °C
Our FSE heating cable is available with output ratings of 17 and 31 W/m, as illustrated in the graph below. The graph shows the nominal output at 230 V when installed on insulated metal pipes.
Maximum Continuous Exposure Temperature (energized) | 100°C |
Maximum Allowable Exposure Temperature (de-energized) | 100°C |
Minimum Operating Temperature | -40ºC |
Temperature Classification | Up to 31 W/m T4 (135°C) |
Power Supply | 12 - 277 VAC |
FSE-CT Cable Dimensions | 12.70 x 5.95mm |
IP Rating | IP67 |
Minimum Installation Temperature | -40°C |
Minimum Bending Radius | -FSE-CT 35mm |
Weight (kg/100 m) | -FSE-CT - 12.4 kg |
Maximum Protective Braid Resistance | 18.2 Ohm/km |
Cable Gland Thread Size | M20 |
The Freezstop Extra Wide (FSEw) self-regulating heating tape provides reliable freeze protection and temperature maintenance for pipes and vessels.
It stands out for its intrinsic safety, installation flexibility, and ability to automatically adjust its output according to the surface temperature.
Maximum Continuous Exposure Temperature (energized) | 100°C |
Maximum Allowable Exposure Temperature (de-energized) | 100°C |
Minimum Operating Temperature | -40ºC |
Temperature Classification | Up to 60 W/m T3 (200°C) |
Power Supply | 12 - 277 VAC |
Cable Dimensions | -FSEw-CT 15.4 x 6.5mm +/- 0.5mm |
Minimum Installation Temperature | -40°C |
Minimum Bending Radius | -FSEw-CT 40mm |
Weight (kg/100 m) | -FSEw-CT - 17.0 kg |
Maximum Protective Braid Resistance | 18.2 Ohm/km |
Cable Gland Thread | M25 |


Maximum Circuit Length (m) according to Breaker Size
Reference | Start-up Temperature (°C) | 230v | 10A | 16A | 20A | 25A |
17FSE | 10 | 46 | 76 | 120 | 148 | |
0 | 36 | 62 | 98 | 122 | 148 | |
-20 | 24 | 42 | 66 | 82 | 102 | |
-40 | 16 | 28 | 44 | 56 | 68 | |
31FSE | 10 | 32 | 52 | 82 | 104 | 110 |
0 | 26 | 42 | 68 | 84 | 106 | |
-20 | 16 | 28 | 46 | 56 | 70 | |
-40 | 12 | 18 | 30 | 38 | 48 | |
To be used with Type C circuit breakers according to IEC 60898 |
Maximum Circuit Length (m) according to Different Breaker Sizes | ||||||
---|---|---|---|---|---|---|
Reference | Start-up Temperature (°C) | 230v 6A | 10A | 16A | 20A | 25A |
45FSEw | 10 | 24 | 38 | 62 | 76 | 96 |
0 | 20 | 32 | 50 | 64 | 80 | |
-20 | 12 | 22 | 34 | 42 | 52 | |
-40 | 8 | 14 | 22 | 28 | 34 | |
60FSEw | 10 | 20 | 35 | 52 | 66 | 82 |
0 | 16 | 28 | 44 | 56 | 70 | |
-20 | 12 | 20 | 32 | 40 | 50 | |
-40 | 8 | 14 | 22 | 28 | 34 | |
For use with Type C circuit breakers in accordance with IEC 60898 |
This self-regulating heating tape is designed for freeze protection and temperature maintenance of pipes and vessels across a wide range of industrial sectors.
Application Example:
For safety and practical reasons, central heating fuel storage tanks are often installed outdoors, in unheated or isolated areas.
Problem Example:
During winter, low temperatures can cause fuel waxing or coagulation. This leads to filter blockages, clogged supply lines, and pumping difficulties, potentially resulting in a complete shutdown of the heating system.
Solution:
One of the most effective ways to prevent these issues is the use of FSE/FSEw heating cables, specifically designed to keep the fuel at an optimal temperature and ensure continuous operation of the central heating system, even under severe climatic conditions.

Self-Regulating Heating Cables – Freezstop Extra (FSE) are used in the following sectors:
-Chemical & Petrochemical
-Water Treatment and Fluid Networks
-Construction and Building
-Food & Beverage Industry
-General Industry
This list is not exhaustive.